Bukwo District

by April 22, 2018

The access rates in Bukwo vary from 54 % in Riwo Sub-County to 95 % in Chesower Sub-County. Bukwo has 638 domestic water points which serve a total of 85,471 people – 78,707 in rural areas. 97 water points have been non-functional for over 5 years and are considered abandoned. Bukwo has 1 piped schemes.

Access

80%

Rural Functionality

88%

Equity

60

Management

92%

Gender

97%

Population Density (people/km2) and Population

50 250 1,000 2,000
  100 500 1,500  
KRT Kortek 634
Kortek
Population 634
BKW Bukwo 333
Bukwo
Population 333
BTC Bukwo TC 984
Bukwo TC
Population 984
CHP Chepkwasta 98
Chepkwasta
Population 98
SNN Senendet 719
Senendet
Population 719
KPT Kaptererwo 279
Kaptererwo
Population 279
RWO Riwo 138
Riwo
Population 138
TLL Tulel 548
Tulel
Population 548
KBI Kabei 459
Kabei
Population 459
SUM Suam 180
Suam
Population 180
CHS Chesower 58
Chesower
Population 58
KMT Kamet 398
Kamet
Population 398

Population figures are projections to the above mentioned date based on UBOS census 2014 and district growth rates. Population density is calculated on land area only. Boundaries reflect the preliminary status only.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 80 %
Rural Access 81 %
Urban Access 75 %

BKW Bukwo 95 %
Bukwo
Population Served 9,586
BTC Bukwo TC 75 %
Bukwo TC
Population Served 6,765
CHP Chepkwasta 95 %
Chepkwasta
Population Served 9,488
CHS Chesower 95 %
Chesower
Population Served 7,413
KBI Kabei 83 %
Kabei
Population Served 6,218
KMT Kamet 88 %
Kamet
Population Served 5,412
KPT Kaptererwo 75 %
Kaptererwo
Population Served 7,756
KRT Kortek 63 %
Kortek
Population Served 4,300
RWO Riwo 54 %
Riwo
Population Served 4,909
SNN Senendet 95 %
Senendet
Population Served 9,983
SUM Suam 60 %
Suam
Population Served 7,700
TLL Tulel 95 %
Tulel
Population Served 5,930

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Access to Safe Water

20 % 60 %
  40 % 80 %
Total Access 80 %
Rural Access 81 %
Urban Access 75 %

BKW Bukwo 95 %
Bukwo
Population Served 9,586
BTC Bukwo TC 75 %
Bukwo TC
Population Served 6,765
CHP Chepkwasta 95 %
Chepkwasta
Population Served 9,488
CHS Chesower 95 %
Chesower
Population Served 7,413
KBI Kabei 83 %
Kabei
Population Served 6,218
KMT Kamet 88 %
Kamet
Population Served 5,412
KPT Kaptererwo 75 %
Kaptererwo
Population Served 7,756
KRT Kortek 63 %
Kortek
Population Served 4,300
RWO Riwo 54 %
Riwo
Population Served 4,909
SNN Senendet 95 %
Senendet
Population Served 9,983
SUM Suam 60 %
Suam
Population Served 7,700
TLL Tulel 95 %
Tulel
Population Served 5,930

Access to safe water is the ratio of people served by a safe water point and piped water supply to the total population.
The calculation is based on an estimated number of people per water point type. Maximum access rate can be 95%.

Functionality of Point Water Sources

60 % 80 %
70 % 90 %
Rural Functionality 88 %
Urban Functionality 47 %

BKW Bukwo 92 %
Bukwo
Functional Sources 98
BTC Bukwo TC 47 %
Bukwo TC
Functional Sources 20
CHP Chepkwasta 97 %
Chepkwasta
Functional Sources 86
CHS Chesower 74 %
Chesower
Functional Sources 42
KBI Kabei 90 %
Kabei
Functional Sources 35
KMT Kamet 91 %
Kamet
Functional Sources 32
KPT Kaptererwo 94 %
Kaptererwo
Functional Sources 46
KRT Kortek 100 %
Kortek
Functional Sources 25
RWO Riwo 78 %
Riwo
Functional Sources 21
SNN Senendet 93 %
Senendet
Functional Sources 65
SUM Suam 59 %
Suam
Functional Sources 29
TLL Tulel 88 %
Tulel
Functional Sources 42

Functionality is the ratio of functional water sources to all water sources. Sources not operating for five or more years are assumed to be abandoned, and hence are not included in the calculation.

People served per technology

Reasons for non-functionality

Type of Management

Source of Funding

District Water Supply Summary

Sub-CountyUrban/
Rural
PopulationPopulation
Served
AccessFunctionalityPoint Water SourcesPiped Water Systems
Protected
springs
Shallow wellsDeep boreholesRainwater
harvesting tanks
DamsValley
tanks
PSP/Kiosk, Tap standsYTHHICNWSC
RUWfPFNFTotFNFTotFNFTotFNFTotFNFTotFNFTotFNFTot
KONGASIS                               
 1 KortekRural6,8684,30063%100%--11-11---------------14-14---No
 2 KametRural6,1405,41288%91%--9-9------2-2------21324---No
 3 KabeiRural7,4936,21883%90%--14216------3-3------18220---No
 4 SuamRural12,8007,70060%59%--437---------------251742---No
 5 Bukwo TCUrban9,0536,76575%-47%-3-3224---3-3------122133---No
 6 RiwoRural9,1584,90954%78%--92113-3-11112------8210---No
 7 TulelRural6,2445,93295%88%--10-10-------11------32537---No
 8 KaptererwoRural10,4067,75675%94%--2-21-12-21-1------40343---No
 9 SenendetRural10,5109,98595%93%--5271-1---3-3------56359---No
 10 BukwoRural10,0949,58995%92%--8191-1---314------86793---No
 11 ChesowerRural7,8057,41595%74%--19-19------213------211435---No
 12 ChepkwastaRural9,9909,49195%97%--18-189-9---1-1------58361---No
Total 106,53285,460808847011210122172192131942300000039180471000No
District 106,53285,460808847011210122172192131942300000039180471000No

F = Functional; NF = Non-Functional; Tot = Total; YT = Yard Tap; HH = Household Connections; IC = Institutional Connections

Piped Water Supply Systems

Type of Scheme/GFSNumber of
Schemes
Functionality of SystemType of ManagementWB in place
FunctionalNon-FunctionalPartially FunctionalPrivate OperatorWSCPrivate/IndividualNWSCOtherYesNo
Unknown/GFS10000000000
Surface Water Based/GFS85020500100
Total95020500100

GFS = Gravity Flow Scheme; WB = Water Board; WSC = Water Source Committee